Fluke Networks DTX1800 Digital Cable Analyzer

  • Fluke DTX-1800
Price:
$3,000.00
SKU:
DTX-1800
Brand:
Availability:
24 Hours
Shipping:
Calculated at checkout
Quantity:
Bookmark and Share


Product Description

Fluke Networks DTX1800 Digital Cable Analyzer

Specifications
*Test Standards
*TIA Category 3, 5e, 6 per ANSI/TIA-568-C.2
*TIA Category 5 (1000BASE-T) per TIA TSB-95
*TIA Category 6 per TIA/EIA-568B.2-1
*TIA Category 6A per ANSI/TIA-568-C.2 (6A DTX-1800 only)
*TIA TSB-155 (DTX-1800 only)
*TR 24750 (DTX-1800 only)
*ISO/IEC 11801 Class C, D, and E
*ISO/IEC 11801 Class Ea, F (DTX-1800 only)
*EN 50173 Class C, D, E
*EN 50173 Class EA, F (DTX-1800 only)
*ANSI TP-PMD
*IEEE 802.3 10BASE-T, 100BASE-TX, 1000BASE-T
*IEEE 802.3an 10GBASE-T

Speed of Autotest
*Full 2-way Autotest of Category 6 Twisted-Pair links in 9 seconds
*Full 2-way Autotest of Category 6A and ISO/IEC Class F links in 22 seconds

Wire Map
Length
Propagation Delay
Delay Skew
DC Loop Resistance
Insertion Loss (Attenuation)
Return Loss (RL), RL @ Remote
NEXT, NEXT @ Remote
Attenuation-to-crosstalk Ratio (ACR-N), ACR-N @ Remote
ACR-F (ELFEXT), ACR-F @ Remote
Power Sum ACR-F (ELFEXT), PS ACR-F @ Remote
Power Sum NEXT, PS NEXT @ Remote
Power Sum ACR-N, PS ACR-N @ Remote
Power Sum Alien Near End Xtalk (PS ANEXT)
Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F)

Cable Tone Generator
Generates tones that can be detected by a tone probe such as a Fluke Networks IntelliTone probe. The tones are generated on all pairs. Frequency range on all pairs. Frequency range of tones: 440 Hz to 831 Hz

Display
3.7 in (9.4 cm) diagonal, 240 dots wide by 320 dots high, passive color, transmissive LCD with backlight.

Input Protection
Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage.

Case
High impact plastic with shock absorbing overmold

Dimensions
Main unit and Smart Remote: 8.5 in x 4.4 in x 2.4 in (21.6 cm x 11.2 cm x 6cm), nominal

Operating Temperature
32°F to 104°F (0°C to 40°C)

Storage Temperature
-4°F to 104°F (-20°C to 60°C)

Operating relative humidity (% RH without condensation)
32°F to 95 °F (0°C to 35°C): 0 % to 90 % 95°F to 113°F (35°C to 45°C): 0 % to 70 %

Vibration
Random, 2 g, 5 Hz -500 Hz

Shock
1 m drop test with and without module and adapter attached

Safety
CSA C22.2 No. 1010.1: 1992 EN 61010-1 1st Edition Amendments 1, 2

Pollution degree
Pollution Degree 2 as defined in IEC 60664 and applied to IEC 60950 "Safety of Information Technology Equipment, 1999"

Altitude
Operating: 4000 m; Storage: 12000 m

EMC
EN 61326-1

Power
Main unit and remote: Lithium-ion battery pack, 7.4 V, 4000 mAh

Typical battery life: 12 to 14 hours
Charge time (with tester off): 4 hours (below 40 °C)
AC adapter/charger, USA version: Linear power supply; Input 108 V ac to 132 V ac, 60 Hz ; Output 15 V dc, 1.2 A
AC adapter/charger, international version: Switching power supply; Input 90 V ac to 264 V ac, 48 to 62 Hz; Output 15 V dc, 1.2 A (isolated output)
Memory backup power in main unit: Lithium battery
Typical life of lithium battery: 5 years
The battery will not charge at temperatures outside of 0°C to 45°C (32°F to 113°F). The battery charges at a reduced rate between 40°C and 45°C (104°F and 113°F).

Languages Supported
English, French, German, Spanish, Portuguese, Italian, Japanese, and Simplified Chinese, Traditional Chinese, Korean, Russian, Czech, Polish, Swedish, Hungarian.

Calibration
Service center calibration period is 1 year

Performance Specifications
Note: all specifications for tests on twisted-pair cabling apply to 100 ?   cable. Contact Fluke Networks for information on measurement performance for cable with a different impedance.

Baseline Accuracy
The baseline accuracy of all DTX Series testers meets or exceeds the requirements of Level IV as in IEC 61935-1/Ed. 3 over the frequency range supported by the tester.

Category 6A/Class EA link test modes (and lower link categories)
DTX CableAnalyzer far exceeds Level III requirements of ANSI/TIA-1152 and IEC 61935-1/Ed.3

Class F link test modes
DTX-1800 is meets or exceeds the requirements of Level IV as in IEC 61935-1/Ed. 3.

Length for Twisted Pair Cabling
(Length specs do not include the uncertainty of the cable's NVP Value)

Parameter
Single-ended Test
Dual-ended Test (Main and Remote)

Range
800 m (2600 ft) - Single-ended Test
150 m (490 ft) - Dual-ended Test (Main and Remote)

Resolution
0.1 m or 1 ft - Single-ended Test
0.1 m or 1 ft - Dual-ended Test (Main and Remote)

Accuracy
± (1m 4%) - Single-ended Test
± (1m 4%) - Dual-ended Test (Main and Remote)

Delay Skew
Parameter Twisted Pair Cabling
Range 0 ns to 100 ns
Resolution 1 ns
Accuracy ± 10 ns

DC Loop Resistance Test Parameter :
Twisted Pair Cabling Range O ?  to 53
Resolution 0.1 ?
Accuracy ± (1 ? 1%)
Overload Recovery Time Less than 10 minutes to rated accuracy following over-voltage. Referencing is required after repeated or prolonged over-voltage.


Find Similar Products by Tag

Networks  fluke  

Find Similar Products by Category


Write your own product review

Product Reviews

This product hasn't received any reviews yet. Be the first to review this product!


Add to Wish List

Click the button below to add the Fluke Networks DTX1800 Digital Cable Analyzer to your wish list.

You Recently Viewed...