Olympus OmniScan MX2 Ultrasonic Detector

This second generation OmniScan MX2 increases testing efficiencies, ensuring superior manual and advanced AUT application performance with faster setups, test cycles, and reporting, in addition to universal compatibility with all phased array and ultrasound modules: past, present and future. Designed for NDT leaders, this high-end, scalable platform delivers true next-generation NDT performance.

The OmniScan MX2 offers a high acquisition rate and new powerful software features for efficient manual and automated inspection performance—all in a portable, modular instrument.

Powerstart your day the right way with the OmniScan MX2. The OmniScan MX2 simplifies and speeds up the setup process with its intuitive Weld Overlay software feature, so you can start testing immediately. Featuring the industry-standard phased array user interface with faster-than-ever performance, a bigger and brighter 10.4 inch screen, new and unique intuitive touch-screen capabilities, and faster data transfer, enabling you to get to your next inspection quicker.

State of the Art P2 and UT2 Modules - As a world leader in phased array technology, Olympus has just released a new line of modules compatible with MX2 instrument.

P2 - The new phased array offer—led by the new innovative P2 modules, features multiple improvements, such as:

Best Phased Array and TOFD Signal Quality Ever
• Better signal-to-noise ratio
• More powerful pulsers
• 64 pure gray tone

More Multi-group CapabilitiesBright, Large Touch Screen
• Ability to use PA and UT channels simultaneously

General Hardware Improvements
• Higher operating temperatures (45 °C)
• New OmniScan probe connector with quick latch system
• Designed for IP66 environmental rating
• Extended autonomy on batteries

UT2 - The new Conventional Ultrasound module features the same technology of UT channels as the PA2 modules, but offers twice as many channels.

Key features

  • Bright, Large Touch Screen
  • New Phased Array and TOFD Modules
  • New NDT SetupBuilder Design Software
  • New OmniPC Analysis Software

Applications

  • Phased Array Weld Inspection
  • ToFD Weld Inspection
  • P/E Weld Inspection
  • General Component Inspection
  • Pressure Vessel Inspection
  • Composite Inspection
  • Corrosion Mapping Inspection
  • Multi-Group Inspection

Technical specifications

STORAGE DEVICES
Storage devices SDHC card, most standard USB storage devices or fast Ethernet
Data file size 300 MB
I/O PORTS
USB ports 3
Speaker out Yes
Video output Video out (SVGA)
Ethernet 10/100 Mbps
I/O LINES
Encoder 2-axis encoder line (quadrature, up, down, or clock/direction)
Digital input 4 digital TTL inputs, 5 V
Digital output 4 digital TTL outputs, 5 V, 15 mA
Acquisition on/off switch Remote acquisition enabled TTL, 5V
Power output line 5 V, 500 mA power output line (short-circuit protected)
Alarms 3 TTL, 5 V, 15 mA
Analog output 2 analog outputs (12 bits) ±5 V in 10 kΩ
Pace input 5 V TTL pace input
DISPLAY
Display size 26.4 cm (10.4 in.) (diagonal)
Resolution 800 pixels x 600 pixels
Brightness 700 cd/m2
Number of colors 16 million
Type TFT LCD
POWER SUPPLY
Battery type Smart Li-ion battery
Number of batteries 1 or 2 (battery chamber accommodates two hotswappable batteries)
Battery life Minimum 7 hours with two batteries
ENVIRONMENTAL SPECIFICATIONS
Operating temperature range -10 °C to 45 °C (14 ºF to 113 ºF)
Storage temperature range –20 °C to 60 °C (–4 ºF to 140 ºF) with batteries –20 °C to 70 °C (–4 ºF to 158 ºF) without batteries
Relative humidity Max. 70% RH at 45°C noncondensing
Ingress Protection Rating IP54
Shockproof rating Drop-tested according to MIL-STD-810G 516.6
Connectors 1 Phased Array connector: Olympus PA connector 2 UT connectors: LEMO 00
Number of focal laws 256
Probe recognition Automatic probe recognition
PULSER/RECEIVER
Aperture 32 elements
Number of elements 128 elements
PULSER
Voltage 40 V, 80 V, and 115 V

95 V, 175 V, and 340 V
Pulse width Adjustable from 30 ns to 500 ns, resolution of 2.5 ns

Adjustable from 30 ns to 1,000 ns; resolution of 2.5 ns
Pulse shape Negative square wave

Negative square wave
Output impedance < 25 Ω

< 30 Ω
RECEIVER
Gain 0 dB to 80 dB, maximum input signal 550 mVp-p (full-screen height)

0 dB to 120 dB maximum input signal 34.5 Vp-p (fullscreen height)
Input impedance 65 Ω

60 Ω in pulse-echo mode 50 Ω in pulse-receive mode
System bandwidth 0.6 MHz to 18 MHz (–3 dB)

0.25 MHz to 28 MHz (-3 dB)
BEAMFORMING
Scan type Sectorial and linear
Group quantity Up to 8
Aperture 32
Number of elements 128
DATA ACQUISITION
Digitizing frequency 400 MHz (12 bits) after interpolation per 4*
Maximum pulsing rate Up to 10 kHz (C-scan)
DATA PROCESSING
Number of data points Up to 8,192
Real-time averaging PA: 2, 4, 8, 16 UT: 2, 4, 8, 16, 32, 64
Rectifier RF, full wave, half wave +, half wave –
Filtering PA Channel: 3 low-pass, 3 band-pass, and 5 high-pass filters. UT channel: 3 low-pass, 6 band-pass, and 3 high-pass filters (8 low-pass filte
Video filtering Smoothing (adjusted to probe frequency range)
DATA VISUALIZATION
A-scan refresh rate Real time: 60 Hz
DATA SYNCHRONIZATION
On internal clock 1 Hz to 10 kHz
On encoder On 2 axes: from 1 to 65,536 steps
PROGRAMMABLE TIME-CORRECTED GAIN (TCG)
Number of points 32: One TCG curve per focal law
ALARMS
Number of alarms 3
Conditions Any logical combination of gates
Analog outputs 2